Electrical Installation Trainer

SKU: PT 980412    Tersedia
  • PT 980412 ELECTRICAL INSTALLATION TRAINER_d
Rp. 96.107.000
Berat: 139,0 Kg

The trainer is designed to provide student with a good foundation in electrical installation. The trainer can be used to teach of house hold and industrial electrical installation. The Electrical installation are able to perform experiments dealing such as : Electrical Measurement, Basic Electrical Control, Electrical Installation, Power Factor Correction. The brake system of three phase AC machine. Controlling speed of three phase AC machine. All input and output on each panel are equipped with safety socket and safety connecting cross 4-mm. Complete with comprehensive experiment manual book to guide student step by step conducting experiments.

  • Three Phase Source [PTE-048-00]
    • Main source voltage 230/380VAC, load maximum 10A
  • Three-Phase NFB [PTE-048-01]
    • 3 main contact, switch load maximum 15A/15kA and nominal voltage 380VAC
  • Three-Phase ELCB [PTE-048-02]
    • 4 main contacts, 3 for line and 1 for neutral, switch maximum load 25A, nominal voltage and fault circuit breaker 30mA
  • Three Phase MCB [PTE-048-03]
    • 3 main contacts and switch load maximum 25A/380VAC, complete with fault simulator for L2 and L3 line on the cover panel
  • Contractor [PTE-048-04]
    • 3 main contact and 1 contact control NO, switch load maximum 25A/380VAC, coil voltage 220VAC/50Hz, complete with fault simulator for L1, L2 line and contact coil on the cover panel
  • Timer Delay [PTE-048-05]
    • Timer delay setting range : 0.1-30ms, 3 main contacts and 3 control contacts, 2 NO, 1 NC, switch load maximum 10A/380VAC, nominal operating voltage 220VAC/50Hz, complete with fault simulator for L2 line, contact and auxiliary contact NO on the cover panel
  • Selected Switch [PTE-048-06]
    • 3 main contact input and 6 main contact output, switch load maximum 15A/220VAC
  • Push-Bottum Change Switches [PTE-048-07]
    • 2 unit push-button, 2 NC contacts and 2 NO contacts, switch load maximum 250VAC/10A
  • Change-Over Switch [PTE-048-08]
    • Flush mounting type 250VAC/10A
  • Indocator Lamps [PTE-048-09]
    • 3 lamps indicator, lamps covers colors : red, yellow, green. Nominal voltage 220 VAC
  • Lamp Socket [PTE-048-10]
    • Nominal voltage 220VAC
  • Single Phase MCB [PTE-048-11]
    • 1 main contact and switch load maximum 25A/380VAC
  • Supply Contractor [PTE-048-12]
    • 3 main contact and 4 control contact, 2 NO ans 2 NC, switch load maximum 25A/380v, coil voltage 220VAC/50Hz, complete with fault smulator for L2 line, contact coil and auxiliary NO contact on the cover panel
  • Thermo Rrelay I [PTE-048-13]
    • 3 pole with overload trip with single phase, setting range : 0.63-1A, auxiliary contacts ; 1 NC, 1 NO, complete with fault simulator for L1 line and NC/NO contact on the cover panel
  • Thermo Relay II [PTE-048-14]
    • 3 pole with overload trip with single phase, setting range : 2.5-4A, auxiliary contacts ; 1 NC, 1 NO, complete with fault simulator for L1 line and NC/NO contact on the cover panel
  • Single Switch [PTE-048-15]
    • Flush mounting type 250VAC/10A. complete with fault simulator on the cover panel
  • Series Switch [PTE-048-16]
    • Flush mounting type 250VAC/10A. complete with fault simulator on the cover panel
  • Schuko Socket [PTE-048-17]
    • Flush mounting type 250V/16A AC, 2-pole with earthen contact
  • Voltmeter [PTE-048-18]
    • Measuring range : 0-500 VAC, instrument : moving coil meter, class 1.5 with selector switch for selecting the phase to measure
  • Amperemeter [PTE-048-19]
    • Measuring range : 0-20 A, instrument : moving coil meter, class 1.5, provided with three current transformers, built in selector switch for selecting the phase to measure
  • Single Phase ELCB [PTE-048-20]
    • 2 main contact for line and neutrak, switch load maximum : 25A, nominal voltage 220VAC, faulty current circuit breaker 30mA
  • Socket Fluorescent Lamps Left [PTE-048-21]
    • Voltage max : 220-250VAC, current max : 3A, starter + socket : 20-40W
  • Ballast Fluorescent Lamps [PTE-048-22]
    • Voltage max : 220VAC, 50Hz, 20/40W 
  • Socket Fluorescent Lamps  Right [PTE-048-23]
    • Voltage masx : 220-250VAC, current max : 3A
  • Capacitive Load [PTE-048-24]
    • Voltage max : 400VAC
    • Capacitor : 3x 1µF; 3x2µF; 3x4µF
  • Pole Changing [PTE-048-25]
    • Max current : 10A, 400V, switch position "2-1-0-1-2"
  • Variabel Power Supply [PTE-048-26]
    • Max current 1A. Output voltage : 0-20VDC
  • Potentiometer [PTE-048-27]
    • Potentiometer 5KΩ/0.25W. Adjustable potentiometer with pointer knob
  • Relay [PTE-048-28]
    • Max. current : 10A, 250V, 3 contact "NC" and 3 contact "NO"
  • Counter [PTE-048-29]
    • Nominal voltage 220V
  • Inventer [PTE-048-30]
    • Nominal voltage 380V, Power 2HP
  • Intermediate Switch [PTE-048-31]
    • Flush mounting type 250VAC/10A, complete with fault simulator on the cover panel
  • Single Phase AC Machine  [PTE-048-32]
    • Motor asynchron, 0.5HP, 4 Pole, 50 Hz, 220VAC, 1450RPM
  • Three-Phase AC Machine 1  [PTE-048-33]
    • Motor asynchron, 1/4HP, 4 Pole, 50 Hz, 220VAC/380VAC, 1450RPM
  • Three-Phase AC Machine 2 [PTE-048-34]
    • Motor asynchron, 2HP, 4 Pole, 50 Hz, 380VAC/660VAC, 1450RPM
  • Three-Phase AC Machine Dual-Speed  [PTE-048-35]
    • Motor asynchron, 1HP, 2/4 Pole, 50 Hz, 380VAC/660VAC, 1500/3000RPM

Covered Topics :

  • LE07001E Lamp Connection with Single Switch
  • LE07002E Lamp Connection with Single Switch and Socket
  • LE07003E Two Lamps Connection with Series Switch and Socket
  • LE07004E Two Way Switching (One Lamp with Change-Over Switch)
  • LE07005E One Lamp with Change-Over Switch and Intermediate Switch
  • LE07006E Power Factor Correction for Fluorescent Lamp Circuit
  • LE07007E Time-Delayed Lighting
  • LE07008E Clockwise and Counter Clockwise System Control with a Switch
  • LE07009E Speed Control of Three Phase Induction Motor Dual Speed with Cam Switch
  • LE07010E Control System Using Magnetic Switch for Single Phase AC Machine
  • LE07011E Control System Using Magnetic Over Load Protection
  • LE07012E Clockwise and Counter Clockwise System Control with Magnetic Switch
  • LE07013E Jogging/Inching Control Completed with Counter
  • LE07014E Star-Delta Circuit
  • LE07015E Speed Control of Three Phase Induction Motor Dual Speed with Magnetic Switch
  • LE07016E The Brake System of Three Phase AC Machine
  • LE07017E Speed Control of Three Phase AC Machine with Inverter